Iso 1217 Annex C

Performance test codes in use today are not suited for a wire-to-air scenario across all technologies. This specification is currently published and available for use when considering positive displacement type blowers. By eliminating it from the rating criteria, the customer can use the volume rating as a starting point to calculate his supply volume based on his specific ambient conditions. That is fine for custom-built compressors, but most compressors sold to industry are not custom-built.

Translations from test conditions to site conditions are not linear and assuming that they are linear results in an inaccurate representation of the actual performance of the blower. The procedure would test the entire blower system including motor, drive, gears, belts, filters, cooling systems, etc. This is a lengthy and detailed test procedure that can be used to verify the actual performance of the equipment before it is shipped to the field. See the table for an example of a simple evaluation that lists four performance points and gives each a weighted average for real process conditions.

The industry is already aware of the need for a new power evaluation and there are several efforts underway to present a wire-to-air specification to meet this need. Please consider this approach in your next blower application. The bucket size did not change but what went into the bucket did.

Related Topics

ISO - Estonian Centre for Standardisation

Volume flow is the volume of air at the standardized reference condition delivered to the terminal point of the compressor package. Remember that this is a volume measurement, so think of it as a bucket that moves cubic feet of something every minute. The dryer has to deal with a given number of pounds of air without regard to the volume that it took to make that number of pounds. The committee largely consists of environmental consultants, manufacturers and end customers. Then, the corresponding kW reading can be recorded to prove any guaranteed kW points offered by the manufacturer.

The relationship between total input power and the amount of flow and pressure produced is replacing a straight efficiency percentage as a comparison criterion. This calculation results in the volume required at the stated summer conditions to deliver the same mass as cubic feet of air at standard conditions.

ISO 1217 Ed 3 Annex C-1996

Beyond evaluation, the manufacturer should have the facilities to perform testing in accordance with the specified code. The code allows for many deviations and does not indicate which processes should be used to measure flow as it allows inlet or discharge flow measurements. Rather, the factors that matter the most for biological processes are input power and pounds of oxygen on the discharge mass flow rate.

Nm3/Hr to m3/Hr FAD Calculations

This is where the standardized reference conditions come into play. Changes in ambient temperature are why some marginal applications work fine in the winter and struggle in the summer.

When comparing power usage, a wire-to-air approach, backed by a published standard, is the only fair and unbiased way to evaluate between technologies. The variable flow or pressure and the power that different blower technologies consume over a range of performances will also have a large impact. This will cause some of the water vapor to condense into a liquid, sudoku printable removing its portion of the inlet air stream from what is available at the discharge point of the dryer. This new version will include methods for testing and reporting variable speed compressors at less than full load levels.

The use of nominal or nameplate efficiencies of the various components will not be allowed. Water vapor drawn into the compressor would never see a temperature lower than that and no water would condense.

Nm3/Hr to m3/Hr FAD Calculations

While a common practice today, using nameplate efficiency data on motors, valves or other accessories reveals loose data sets that vary greatly between manufacturers. The translation from test conditions to site conditions is also not very clear and subject to interpretation. Power consumption, while important, is just one criterion in the selection of blower technology.

Industrial Utility Efficiency. This was done to allow users to look at performance over the flow range they actually need and not at just the full load point. Now divide by the correction factors. Multiplying these two correction factors together give you the total change in density of the ambient air between the site conditions and the standard conditions.

This specification has been amended to include a wire-to-air annex as listed below. The definition of wire-to-air will include all the actual components required and supplied on the particular application and will be tested as a working system over a range of operating points. The customer will also need to use the reference pressure and temperature in that calculation. The basic premise is to evaluate how the blower will work across the entire range of its expected operation.

Instead of relying on just one particular flow and pressure to compare energy usage, dynamic performance should also be noted when measuring the evaluated power usage over a range of operations. If the facility happened to be in Denver, some calculations would have to be made to determine whether the compressor would actually operate the device. Each have all the same basic components, a compressor, motor, starter and inlet filter, and some technologies also have cooling systems, an oil pump, gears, belts, couplings and control systems. Also note that air densities are accounted for, given that temperature, humidity and elevation all impact performance. It shows power and flow at minimum speed, maximum speed and at least three equal points between those two speeds.

ISO Ed 3 Annex C

ISO Ed 3 Annex C

Further, the performance verification process is difficult to prove. It was written for positive displacement lobe type blowers.

This specification is obsolete and no longer active. This code only covers the power that is based on the shaft power to the element and does not cover losses across the motor or any other part of the blower system. In the absence of official third party specifications on energy efficiency, it is difficult to evaluate and compare blower technologies fairly and effectively. This specification encourages routine tests that report base performance on a wire-to-air format of positive displacement blower packages. Such a test can only be done in a qualified testing facility under controlled conditions and not in the field.

The evaluation would measure the total energy consumption used by the entire blower system in real world conditions, while taking into account all potential energy losses. From there, calculations can easily be made to adjust the volume rating to the actual site conditions.

Displacement compressors -- Acceptance tests